LMV RANGE
CONNECTOR WIRING INSTRUCTIONS

USING MULTICORE CABLE WITH INNER COLLECTIVE SCREEN

1
Strip outer sheath and braid.
Thread onto cable - union nut (or cable clamp), packing piece, union gasket (see note), compression ring and cable sleeve.
Comb out metal braid, fold back over outer sheath and tape down.
Strip insulation 3.0mm from conductors and tin.
Thread on outlet nut, outlet and retaining gland.

NOTE:
Union gasket must be a close fit to cable sheath. Synthetic rubber sleeves may be used to achieve required fit.


  Dimension A mm
Straight
Outlet
Right Angle
Outlet
Sheath 22.0 30.0
Braid 9.5 16.0


2
Solder conductors to connector contacts brown - L, blue - N, green/yellow - E and slide retaining gland over joints.
Position outlet and secure with outlet nut.
Slide cable sleeve into neck of outlet.
3
Remove tape from metal braid and fan out 90º to cable.
Position compression ring on end of outer sheath, trapping braid between outlet and compression ring.
Slide forward union gasket and packing piece to rear of compression ring.
Trim off braid to rear face of compression ring and screw union nut (or clamp) onto outlet. (Tighten cable clamp, if used.)



USING MULTICORE CABLE TOTALLY UNSCREENED
1
Strip outer sheath as follows:
Straight outlet dimensions ‘A’ 22.0mm
Right angle outlet dimension ‘A’ 30mm
Strip and tin each lead 3.0mm
Thread on components in order shown.
2
Solder conductors to connector contacts
brown - L, blue - N, yellow/green - E.
Slide retaining gland forward over joints.
Position outlet and secure with outlet nut.
Slide gland plug into neck of outlet and screw on to outlet.
Screw down clamp jaw on to gland plug.

Next Page>>