LMV RANGE CONNECTOR WIRING INSTRUCTIONS |
||||||||||||
|
USING MULTICORE CABLE WITH INNER COLLECTIVE SCREEN
1 |
||||||||||||
![]()
|
||||||||||||
2 Solder conductors to connector contacts brown - L, blue - N, green/yellow - E and slide retaining gland over joints. Position outlet and secure with outlet nut. Slide cable sleeve into neck of outlet. |
||||||||||||
![]() |
||||||||||||
| 3 Remove tape from metal braid and fan out 90º to cable. Position compression ring on end of outer sheath, trapping braid between outlet and compression ring. Slide forward union gasket and packing piece to rear of compression ring. Trim off braid to rear face of compression ring and screw union nut (or clamp) onto outlet. (Tighten cable clamp, if used.) |
||||||||||||
![]() |
||||||||||||
| USING MULTICORE CABLE TOTALLY UNSCREENED | ||||||||||||
| 1 Strip outer sheath as follows: Straight outlet dimensions ‘A’ 22.0mm Right angle outlet dimension ‘A’ 30mm Strip and tin each lead 3.0mm Thread on components in order shown. |
||||||||||||
![]() |
||||||||||||
| 2 Solder conductors to connector contacts brown - L, blue - N, yellow/green - E. Slide retaining gland forward over joints. Position outlet and secure with outlet nut. Slide gland plug into neck of outlet and screw on to outlet. Screw down clamp jaw on to gland plug. |
||||||||||||
![]() |
||||||||||||
|
|
||||||||||||
|
|
||||||||||||
|
|
||||||||||||