LMHF RANGE LMHF EMI SUPPRESSION FILTER CONNECTORS |
|||
![]() |
|||
|
FILTER TYPES AVAILABLE |
|||
|
All measurements in this
catalogue are quoted in reference to a 50 Ohm system. The
performance of a suppression filter is normally measured in a circuit
where both the source and load impedance are 50 Ohms. 50 Ohms is
considered to be an industry standard for many practical reasons.
However, should a situation arise where the system is not 50 Ohms we can
provide graphs of typical insertion loss on request. |
|||
| Circuit Styles | Electrical Characteristics | ||
|
C STYLE CAPACITANCE
FILTER
LC INDUCTOR AND CAPACITOR
Pi CAPACITOR x 2 PLUS 1
INDUCTOR
|
Dielectric withstand voltage | 500V DC | |
| Earth path | 5mW | ||
| Working Voltage | 200V DC - 125V ac rms | ||
| Current | 7.5amp (size 20 contact) | ||
| Temperature | -55°c
to +125°C De-rates linearly between 85°c and 125°c 200V DC @ 85°c becomes 100V DC @ 125°c |
||
| Insulation resistance | 100 MW @ 25°c | ||
| Contact resistance | 5mW @ 25°c | ||
| Tested
to Weald Specification WES 039. Copy available on request. |
|||
|
|||
|
|
|||
|
|
|||